Free Standard AU & NZ Shipping For All Book Orders Over $80!
Register      Login
International Journal of Wildland Fire International Journal of Wildland Fire Society
Journal of the International Association of Wildland Fire
RESEARCH ARTICLE

Assessing the flammability of surface fuels beneath ornamental vegetation in wildland–urban interfaces in Provence (south-eastern France)

Anne Ganteaume A B , Marielle Jappiot A and Corinne Lampin A
+ Author Affiliations
- Author Affiliations

A Irstea UR EMAX, 3275 route de Cézanne, CS 40061, F-13182 Aix-en-Provence, cedex 5, France.

B Corresponding author. Email: anne.ganteaume@irstea.fr

International Journal of Wildland Fire 22(3) 333-342 https://doi.org/10.1071/WF12006
Submitted: 12 January 2012  Accepted: 30 July 2012   Published: 3 October 2012

Abstract

The objectives of this paper are to assess in laboratory conditions the flammability of undisturbed litter sampled beneath plants of seven species that are among those most frequently planted in hedges in Provence (south-eastern France). The variability in litter flammability recorded during burning experiments was partly explained by the proportions of the different litter components of each species. Phyllostachys sp. and Nerium oleander litters were the quickest to ignite whereas Prunus laurocerasus litter had the lowest bulk density and long time-to-ignition, but high flame-propagation. Photinia fraseri litter ignited frequently and had a high flame spread whereas Pittosporum tobira litter ignited the least frequently and for the shortest duration. Cupressus sempervirens litter had the highest bulk density and the longest flaming duration but the lowest flame propagation. Pyracantha coccinea litter was the slowest to ignite and flame propagation was low but lasted a long time. Co-inertia analysis identified species with the same flammability characteristics according to the composition of their litter. Hierarchical cluster analysis ranked the seven species in four distinct clusters from the most flammable (Photinia fraseri and Prunus laurocerasus) to the least flammable (Pittosporum tobira), the other species displaying two groups of intermediate flammability. These latter species should not be used in hedges planted in wildland–urban interfaces in south-eastern France.

Additional keywords: flammability variables, hedge, litter composition, undisturbed litter.


References

Anderson HE (1970) Forest fuel ignitability. Fire Technology 6, 312–319.
Forest fuel ignitability.Crossref | GoogleScholarGoogle Scholar | 1:CAS:528:DyaE3MXhsVent7g%3D&md5=2fc71aac5fdf777e23da4166e7e60004CAS |

Babrauskas V (2002) Heat release rates. In ‘The SFPE Handbook of Fire Protection and Engineering’, 3rd edn. pp. 3-1–3-37. (National Fire Protection Association: Quincy, MA)

Babrauskas V (2003) ‘Ignition Handbook.’ (Fire science publishers: Issaquah, WA)

Baeza MJ, De Luis M, Raventos J, Escarre A (2002) Factors influencing fire behaviour in shrublands of different stand ages and the implications for using prescribed burning to reduce wildfire risk. Journal of Environmental Management 65, 199–208.
Factors influencing fire behaviour in shrublands of different stand ages and the implications for using prescribed burning to reduce wildfire risk.Crossref | GoogleScholarGoogle Scholar | 1:STN:280:DC%2BD38vjvFKjtA%3D%3D&md5=b0dc8964e093fecd6dea58630a686537CAS |

Behm AL, Duryea ML, Long AJ, Zipperer WC (2004) Flammability of native understory species in pine flatwood and hardwood hammock ecosystems and implications for the wildland–urban interface. International Journal of Wildland Fire 13, 355–365.
Flammability of native understory species in pine flatwood and hardwood hammock ecosystems and implications for the wildland–urban interface.Crossref | GoogleScholarGoogle Scholar |

Bond WJ, Van Wilgen BW (1996) ‘Fire and Plants.’ (Chapman and Hall: London, UK)

Bradstock RA, Cohn JS (2002) Fire regimes and biodiversity in semi-arid mallee ecosystems. In ‘Flammable Australia: the Fire Regimes and Biodiversity of a Continent’. (Eds RA Bradstock, JE Williams, AM Gill) pp. 238–258. (Cambridge University Press: Cambridge, UK)

Chuvieco E, Aguado I, Dimitrakopoulos AP (2004) Conversion of fuel moisture content values to ignition potential for integrated fire danger assessment. Canadian Journal of Forest Research 34, 2284–2293.
Conversion of fuel moisture content values to ignition potential for integrated fire danger assessment.Crossref | GoogleScholarGoogle Scholar |

Curt T, Schaffhauser A, Borgniet L, Dumas C, Estève R, Ganteaume A, Jappiot M, Martin W, N’Diaye A, Poilvet B (2011) Litter flammability in oak woodlands and shrublands of southeastern France. Forest Ecology and Management 261, 2214–2222.
Litter flammability in oak woodlands and shrublands of southeastern France.Crossref | GoogleScholarGoogle Scholar |

de la Riva J, Perez-Cabello F (2005) El factor humano en el riesgo de incendios forestales a escala municipal. Aplicación de técnicas SIG para su modelización. In ‘La ciencia forestal: respuestas para la sostenibilidad: 4th Congreso Forestal Español’, 26–30 September 2005, Zaragoza, Spain. (Sociedad Española de Ciencias Forestales: Madrid)

de la Riva J, Perez-Cabello F, Chuvieco E (2006) Wildland fire ignition danger spatial modelling using GIS and satellite data. In EGU General Assembly – European Geosciences Union. Geophysical Research Abstracts 8, 10 321

Delabraze P, Valette J-C (1974) Inflammabilité et combustibilité de la végétation forestière méditerranéenne. Revue Forestière Française Numéro spécial, 171–177.

Dimitrakopoulos AP (2001) A statistical classification of Mediterranean species based on their flammability components. International Journal of Wildland Fire 10, 113–118.
A statistical classification of Mediterranean species based on their flammability components.Crossref | GoogleScholarGoogle Scholar |

Dimitrakopoulos AP, Panov PI (2001) Pyric properties of some dominant Mediterranean vegetation species. International Journal of Wildland Fire 10, 23–27.
Pyric properties of some dominant Mediterranean vegetation species.Crossref | GoogleScholarGoogle Scholar |

Dimitrakopoulos AP, Papaioannou KK (2001) Flammability assessment of Mediterranean forest fuels. Fire Technology 37, 143–152.
Flammability assessment of Mediterranean forest fuels.Crossref | GoogleScholarGoogle Scholar |

Dolédec S, Chessel D (1994) Co-inertia analysis; an alternative method for studying species-environment relationships. Freshwater Biology 31, 277–294.
Co-inertia analysis; an alternative method for studying species-environment relationships.Crossref | GoogleScholarGoogle Scholar |

Etlinger MG, Beall FC (2004) Development of a laboratory protocol for fire performance of landscape plants. International Journal of Wildland Fire 13, 479–488.
Development of a laboratory protocol for fire performance of landscape plants.Crossref | GoogleScholarGoogle Scholar |

Frandsen W (1997) Ignition probability of organic soils. Canadian Journal of Forest Research 27, 1471–1477.
Ignition probability of organic soils.Crossref | GoogleScholarGoogle Scholar |

Ganteaume A, Lampin C, Guijarro M, Hernando C, Jappiot M, Fonturbel T, Perez-Gorostiaga P, Vega JA (2009) Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds. International Journal of Wildland Fire 18, 951–969.
Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds.Crossref | GoogleScholarGoogle Scholar | 1:CAS:528:DC%2BD1MXhsFaqtLzO&md5=757d700f70559f5122b6173653fef268CAS |

Ganteaume A, Jappiot M, Lampin-Maillet C, Curt T, Borgniet L (2011a) Effects of vegetation type and fire regime on flammability of undisturbed litters in South-Eastern France. Forest Ecology and Management 261, 2223–2231.
Effects of vegetation type and fire regime on flammability of undisturbed litters in South-Eastern France.Crossref | GoogleScholarGoogle Scholar |

Ganteaume A, Guijarro M, Jappiot M, Hernando C, Lampin-Maillet C, Perez-Gorostiaga P, Vega JA (2011b) Laboratory characterization of firebrands involved in spot fires. Annals of Forest Science 68, 531–541.
Laboratory characterization of firebrands involved in spot fires.Crossref | GoogleScholarGoogle Scholar |

Glitzenstein JL, Streng DR, Achtmeier GL, Naeher LP, Wade DD (2006) Fuels and fire behavior in chipped and unchipped plots: implications for land management near the wildland/urban interface. Forest Ecology and Management 236, 18–29.
Fuels and fire behavior in chipped and unchipped plots: implications for land management near the wildland/urban interface.Crossref | GoogleScholarGoogle Scholar |

Jappiot M, Lampin C, Curt T, Ganteaume A, Borgniet L, Bouillon Ch, Chandioux O, Estève R, Long M, Martin W, Morge D, Alexandrian D, D’Avezac H, Tatoni T, Dumas E, Valette J-C, Moro C (2007) Modélisation et cartographie de l’aléa d’éclosion d’incendie de forêt. Programme AIOLI. Convention DGFAR 61.45.80.31/04 1. Convention DPFM du 06 décembre 2005. Cemagref, Rapport final. (Aix en Provence, France)

Jerman JL, Gould PJ, Fulé PZ (2004) Slash compression treatment reduced tree mortality from prescribed fire in south-western ponderosa pine. Western Journal of Applied Forestry 19, 149–153.

Lawson B, Armitage B, Dalrymple GN (1996) Wildfire Ignition Probability Predictor (WIPP). Canadian Forest Service, Pacific Forestry Center, R&D Update. (Victoria, BC)

Leone V, Koutsias N, Martínez J, Vega-García C, Allgöwer B, Lovreglio R (2003) The human factor in fire danger assessment. In ‘Wildland Fire Danger Estimation and Mapping: the Role of Remote Sensing Data’. (Ed. E. Chuvieco) pp. 143–196. (World Scientific: Hackensack, NJ)

Long AJ, Behm A, Zipperer WC, Hermansen A, Maranghides A, Mell W (2006a) Quantifying and ranking the flammability of ornamental shrubs in the southern United States. In ‘2006 Fire Ecology and Management Congress Proceedings’, 13–17 November 2006, San Diego, CA. (DVD) (The Association for Fire Ecology and Washington State University Extension: San Diego, CA)

Long A, Hinton B, Zipperer W, Hermansen-Baez A, Maranghides A, Mell W (2006b) Fire spread and structural ignitions from horticultural plantings in the wildland–urban interface. In ‘Fire Ecology and Management Congress Proceedings’, 13–17 November 2006, San Diego, CA. (DVD) (The Association for Fire Ecology and Washington State University Extension: San Diego, CA)

Lubin DM, Shelly JR (1997) Defensible space landscaping in the urban/wildland interface: a compilation of fire performance ratings of residential landscape plants. University of California, Forest Products Laboratory, Internal Report Number 36.01.137. (Richmond, CA)

Manzello SL, Cleary TG, Shields JR, Yang JC (2006a) On the ignition of fuel beds by firebrands. Fire and Materials 30, 77–87.
On the ignition of fuel beds by firebrands.Crossref | GoogleScholarGoogle Scholar | 1:CAS:528:DC%2BD28XhslOnu70%3D&md5=3f49b2697bd2a237db507b14c996b0caCAS |

Manzello SL, Cleary TG, Shields JR, Yang JC (2006b) Ignition of mulch and grasses by firebrands in wildland–urban interface fires. International Journal of Wildland Fire 15, 427–431.
Ignition of mulch and grasses by firebrands in wildland–urban interface fires.Crossref | GoogleScholarGoogle Scholar |

Manzello SL, Maranghides A, Mell WE (2007) Firebrand generation from burning vegetation. International Journal of Wildland Fire 16, 458–462.
Firebrand generation from burning vegetation.Crossref | GoogleScholarGoogle Scholar |

Manzello SL, Cleary TG, Shields JR, Maranghides A, Mell W, Yang JC (2008) Experimental investigations of firebrands: generation and ignition of fuel beds. Fire Safety Journal 43, 226–233.
Experimental investigations of firebrands: generation and ignition of fuel beds.Crossref | GoogleScholarGoogle Scholar | 1:CAS:528:DC%2BD1cXktlejtrY%3D&md5=1d2dcecd953377dafac3edd5e6aa45ebCAS |

Manzello SL, Park SH, Cleary TG (2009) Investigation on the ability of glowing firebrands deposited within crevices to ignite common building materials. Fire Safety Journal 44, 894–900.
Investigation on the ability of glowing firebrands deposited within crevices to ignite common building materials.Crossref | GoogleScholarGoogle Scholar | 1:CAS:528:DC%2BD1MXotlOltLw%3D&md5=9355fab3952435879abfc36bc0e96f5bCAS |

Martin RE, Gordon DA, Gutierrez ME, Lee DS, Molina DM, Schroeder RA, Sapsis DB, Stephens SL, Chambers M (1994) Assessing the flammability of domestic and wildland vegetation. In ‘Proceedings of the 12th Conference on Fire and Forest Meteorology’, 26–28 October 1993, Jekyll Island, GA. pp. 130–137 (Society of American Foresters: Bethesda, MD)

Monroe MC, Long AJ, Marynowski S (2003) Wildland fire in the Southeast: negotiating guidelines for defensible space. Journal of Forestry 101, 14–19.

Moretti M, Legg C (2009) Combining plant and animal traits to assess community functional responses to disturbance. Ecography 32, 299–309.
Combining plant and animal traits to assess community functional responses to disturbance.Crossref | GoogleScholarGoogle Scholar |

Ormeño E, Céspedes B, Sánchez IA, Velasco-García A, Moreno J, Fernandez C, Baldy V (2009) The relationship between terpenes and flammability of leaf litter. Forest Ecology and Management 257, 471–482.
The relationship between terpenes and flammability of leaf litter.Crossref | GoogleScholarGoogle Scholar |

Parker WJ, LeVan SL (1989) Kinetic properties of the components of Douglas-fir and the heat of combustion of their volatile pyrolysis products. Wood and Fiber Science 21, 289–305.

Pellizzaro G, Duce P, Ventura A, Zara P (2007) Seasonal variations of live moisture content and ignitability in shrubs of the Mediterranean Basin. International Journal of Wildland Fire 16, 633–641.
Seasonal variations of live moisture content and ignitability in shrubs of the Mediterranean Basin.Crossref | GoogleScholarGoogle Scholar |

Petriccione M, Moro C, Rutigliano FA (2006) Preliminary studies on litter flammability in Mediterranean region. Forest Ecology and Management 234, S126

Plucinski MP, Anderson WR (2008) Laboratory determination of factors influencing successful point ignition in the litter layer of shrubland vegetation. International Journal of Wildland Fire 17, 628–637.
Laboratory determination of factors influencing successful point ignition in the litter layer of shrubland vegetation.Crossref | GoogleScholarGoogle Scholar |

Pyne SJ, Andrews PL, Laven RD (1996) ‘Introduction to Wildland Fire’, 2nd edn. (Wiley: New York)

R Development Core Team (2005) R: A Language and Environment for Statistical Computing, Reference Index Version v. 2.5.1. (R Foundation for Statistical Computing: Vienna, Austria)

Scarff FR, Westoby M (2006) Leaf litter flammability in some semi-arid Australian woodlands. Functional Ecology 20, 745–752.
Leaf litter flammability in some semi-arid Australian woodlands.Crossref | GoogleScholarGoogle Scholar |

ter Braak CJF, Schaffers AP (2004) Co-correspondence analysis: a new ordination method to relate two community compositions. Ecology 85, 834–846.
Co-correspondence analysis: a new ordination method to relate two community compositions.Crossref | GoogleScholarGoogle Scholar |

Thioulouse J, Chessel D, Doledec S, Olivier JM (1997) ADE-4: a multivariate analysis and graphical display software. Statistics and Computing 7, 75–83.
ADE-4: a multivariate analysis and graphical display software.Crossref | GoogleScholarGoogle Scholar |

Valette JC (1990) Flammability of Mediterranean forest species. Effects on the combustibility of vegetation types. Revue Forestière Française Numéro spécial, 76–92.

Vines RG (1981) Physics and chemistry of rural fires. In ‘Fire and the Australian Biota’. (Eds RM Gill, RH Groves, IR Noble) pp. 129–149. (Australian Academy of Science: Canberra)

Weise DR, White RH, Beall FC, Etlinger M (2005) Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire 14, 321–338.
Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation.Crossref | GoogleScholarGoogle Scholar |

White RH, Zipperer WC (2010) Testing and classification of individual plants for fire behaviour: plant selection for the wildland–urban interface. International Journal of Wildland Fire 19, 213–227.
Testing and classification of individual plants for fire behaviour: plant selection for the wildland–urban interface.Crossref | GoogleScholarGoogle Scholar |

White RH, DeMars D, Bishop M (1997) Flammability of Christmas trees and other vegetation. In ‘Proceedings of the 24th international conference on fire safety’, 21–24 July 1997, Columbus, OH. (Ed. CJ Hilado) pp. 99–110 (Products Safety Corporation: Sissonville, WV)