Deviations from Matthiessen's Rule for Cold–Drawn Wires
GJ Ogilvie and WK Clothier
Australian Journal of Physics
7(1) 210 - 216
Published: 1954
Abstract
An A.C. bridge method of high accuracy has been developed to measure deviations from Matthiessen's rule. Deviations have been shown to exist in cold-drawn wires of copper, aluminium, bronze, and 80/20 brass.https://doi.org/10.1071/PH540210