Intravascular device use, management, documentation and complications: a point prevalence survey
Karen A. New A B D , Joan Webster A B C , Nicole M. Marsh A C , Barbara Hewer A and on behalf of the Royal Brisbane and Women’s Hospital Intravenous Access Research CouncilA Centre for Clinical Nursing, 2nd Floor, Centre for Clinical Nursing, Building 34, Royal Brisbane and Women’s Hospital, Butterfield Street, Herston, Qld 4029, Australia. Email: Joan.Webster@health.qld.gov.au; Nicole.Marsh@health.qld.gov.au; Barbara.Hewer@health.qld.gov.au
B The University of Queensland, School of Nursing and Midwifery, 2nd Floor, Centre for Clinical Nursing, Building 34, Royal Brisbane and Women’s Hospital, Butterfield Street, Herston, Qld 4029, Australia.
C NHMRC Centre for Research Excellence in Nursing, Centre for Health Practice Innovation, Griffith Health Institute, Griffith University, 2nd Floor, Centre for Clinical Nursing, Building 34, Royal Brisbane and Women’s Hospital, Butterfield Street, Herston, Qld 4029, Australia.
D Corresponding author. Email: k.new@uq.edu.au
Australian Health Review 38(3) 345-349 https://doi.org/10.1071/AH13111
Submitted: 31 May 2013 Accepted: 2 March 2014 Published: 29 May 2014
Abstract
Objective To examine the use, management, documentation and complications for intravascular devices in cardiac, medical and surgical inpatients.
Methods A point prevalence survey was undertaken in a large tertiary hospital in Queensland. Descriptive statistics were used to analyse data.
Results Of the 327 patients assessed, 192 (58.7%) had one or more devices in situ. Of the 220 devices, 190 (86.4%) were peripheral venous catheters, 25 (11.4%) were peripherally inserted central catheters and five (2.3%) were central venous catheters. Sixty-two of 220 devices (28.2%) were in situ without a clear purpose, whereas 54 (24.7%) had one or more complications, such as redness, pain, tracking, oedema or oozing. There was no documentation on the daily patient care record to indicate that a site assessment had occurred within the past 8 h for 25% of the devices in situ.
Conclusions The present study identified several problems and highlighted areas for improvement in the management and documentation for intravascular devices. Ongoing education, promoting good clinical practice and reauditing, can be applied to improve the management of devices.
What is known about the topic? Intravascular devices are associated with health care-related infections, including rare but serious bloodstream infections Measures for reducing healthcare-associated infection related to devices include surveillance with feedback.
What does this paper add? This paper complements other surveillance data undertaken in similar-sized institutions with similar patients. Ongoing surveillance and education is required to maintain best clinical practice and management of devices.
What are the implications for practitioners? Health care-associated infections are a serious problem and have negative outcomes for both patients and organisations. Intravascular devices may be associated with bloodstream infections, so prudent clinical care and management of devices is important. All devices should be assessed at least daily for their continued need and removed promptly if no longer required.
References
[1] Pujol M, Hornero A, Saballs M, Argerich M, Verdaguer R, Cisnal M, Peña C, Ariza J, Gudiol F. Clinical epidemiology and outcomes of peripheral venous catheter-related bloodstream infections at a university-affiliated hospital. J Hosp Infect 2007; 67 22–9.| Clinical epidemiology and outcomes of peripheral venous catheter-related bloodstream infections at a university-affiliated hospital.Crossref | GoogleScholarGoogle Scholar | 1:STN:280:DC%2BD2srktVOnsA%3D%3D&md5=afd7752a241196d6174027ad41633ee6CAS | 17719678PubMed |
[2] Rickard C, Webster J, Wallis M, Marsh N, McGrail M, French V, Foster L, Gallagher P, Gowardman JR, Zhang L, McClymont A, Whitby M. Routine versus clinically indicated replacement of peripheral intravenous catheters: a randomised controlled equivalence trial. Lancet 2012; 380 1066–74.
| Routine versus clinically indicated replacement of peripheral intravenous catheters: a randomised controlled equivalence trial.Crossref | GoogleScholarGoogle Scholar | 22998716PubMed |
[3] Zingg W, Pittet D. Peripheral venous catheters: an under-evaluated problem. Int J Antimicrob Agents 2009; 34 S38–42.
| Peripheral venous catheters: an under-evaluated problem.Crossref | GoogleScholarGoogle Scholar | 1:CAS:528:DC%2BD1MXhsVKntbrP&md5=a4c0eabe112982f2955444778590899cCAS | 19931816PubMed |
[4] Curran ET, Coia JE, Gilmour H, McNamee S, Hood J. Multi-centre research surveillance project to reduce infections/phlebitis associated with peripheral vascular catheters. J Hosp Infect 2000; 46 194–202.
| 1:STN:280:DC%2BD3M7ivVKisQ%3D%3D&md5=32ee56b879516b1c586e3f74d87589e9CAS | 11073728PubMed |
[5] Durlach R, McIlvenny G, Newcombe R, Reid G, Doherty L, Freuler C, Rodríguez V, Duse AG, Smyth ET. Prevalence survey of healthcare-associated infections in Argentina; comparison with England, Wales, Northern Ireland and South Africa. J Hosp Infect 2012; 80 217–23.
| Prevalence survey of healthcare-associated infections in Argentina; comparison with England, Wales, Northern Ireland and South Africa.Crossref | GoogleScholarGoogle Scholar | 1:STN:280:DC%2BC383ksF2rsA%3D%3D&md5=1bcaa3770b42d3356f56d56d43433d22CAS | 22230102PubMed |
[6] Maki D, Kluger M, Crnich C. The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc 2006; 81 1159–71.
| The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies.Crossref | GoogleScholarGoogle Scholar | 16970212PubMed |
[7] Spencer R. Novel methods for the prevention of infection of intravascular devices. J Hosp Infect 1999; 43 S127–35.
| Novel methods for the prevention of infection of intravascular devices.Crossref | GoogleScholarGoogle Scholar | 10658768PubMed |
[8] Berenholtz SM, Pronovost PJ, Lipsett PA, Hobson D, Earsing K, Farley JE, Milanovich S, Garrett-Mayer E, Winters BD, Rubin H, Dorman T, Perl T. Eliminating catheter-related bloodstream infections in the intensive care unit. Crit Care Med 2004; 32 2014–20.
| Eliminating catheter-related bloodstream infections in the intensive care unit.Crossref | GoogleScholarGoogle Scholar | 15483409PubMed |
[9] Graves N, Halton K, Paterson D, Whitby M. Economic rationale for infection control in Australian hospitals. Healthc Infect 2009; 14 81–8.
| Economic rationale for infection control in Australian hospitals.Crossref | GoogleScholarGoogle Scholar |
[10] Goddard L, Clayton S, Peto T, Bowler I. The ‘just-in-case venflon’: effect of surveillance and feedback on prevalence of peripherally inserted intravascular devices. J Hosp Infect 2006; 64 401–2.
| The ‘just-in-case venflon’: effect of surveillance and feedback on prevalence of peripherally inserted intravascular devices.Crossref | GoogleScholarGoogle Scholar | 1:STN:280:DC%2BD28nmtFantg%3D%3D&md5=4469466824164a93a8f7c9bb5c995d31CAS | 17046109PubMed |
[11] Ritchie S, Jowitt D, Roberts S. The Auckland City hospital device point prevalence survey 2005: utilisation and infectious complications of intravascular and urinary devices. N Z Med J 2007; 120 U2683
| 17726497PubMed |
[12] Thomas A, Hayes P, Lockie T, Harrington D. Venflons: why can’t we resist putting them in? J Hosp Infect 2006; 63 108–9.
| Venflons: why can’t we resist putting them in?Crossref | GoogleScholarGoogle Scholar | 1:STN:280:DC%2BD283isVKiuw%3D%3D&md5=f29cf05d529aa1331987d9271aa14920CAS | 16517008PubMed |
[13] Robertson MS, Nichol AD, Higgins AM, Bailey MJ, Presneill JJ, Cooper DJ, Webb SA, McArthur C, MacIsaac CM, VTE Point Prevalence Investigators for the Australian and New Zealand Intensive Care Research Centre; Australian and New Zealand Intensive Care Society Clinical Trials Group Venous thromboembolism prophylaxis in the critically ill: a point prevalence survey of current practice in Australian and New Zealand intensive care units. Crit Care Resusc 2010; 12 9–15.
| 20196708PubMed |
[14] Australian Commission on Safety and Quality in health Care (ACSQHC). National Safety and quality health service standards. Sydney: ACSQHS; 2011.
[15] McHugh S, Corrigan M, Dimitrov B, Morris-Downes M, Fitzpatrick F, Cowman S, Tierney S, Hill AD, Humphreys H. Role of patient awareness in prevention of peripheral vascular catheter-related bloodstream infection. Infect Control Hosp Epidemiol 2011; 32 95–6.
| Role of patient awareness in prevention of peripheral vascular catheter-related bloodstream infection.Crossref | GoogleScholarGoogle Scholar | 21087126PubMed |
[16] Benner K, Lucas A. ASHP therapeutic position statement on the institutional use of 0.9% sodium chloride injection to maintain patency of peripheral indwelling intermittent infusion devices. Am J Health Syst Pharm 2012; 69 1252–4.
| ASHP therapeutic position statement on the institutional use of 0.9% sodium chloride injection to maintain patency of peripheral indwelling intermittent infusion devices.Crossref | GoogleScholarGoogle Scholar | 22761082PubMed |
[17] Gabriel J. Vascular access devices: securement and dressings. Nurs Stand 2010; 24 41–6.
| Vascular access devices: securement and dressings.Crossref | GoogleScholarGoogle Scholar | 20860214PubMed |
[18] Russell E, Chan R, Marsh N, New K. A point prevalence study of cancer nursing practices for managing intravascular devices in an Australian tertiary cancer center. Eur J Oncol Nurs 2013;
| A point prevalence study of cancer nursing practices for managing intravascular devices in an Australian tertiary cancer center.Crossref | GoogleScholarGoogle Scholar | 24373944PubMed |