Free Standard AU & NZ Shipping For All Book Orders Over $80!
Register      Login
Exploration Geophysics Exploration Geophysics Society
Journal of the Australian Society of Exploration Geophysicists
RESEARCH ARTICLE

MULTIPULSE – high resolution and high power in one TDEM system

Tianyou Chen 1 2 Greg Hodges 1 Philip Miles 1
+ Author Affiliations
- Author Affiliations

1 CGG, 2505 Meadowvale Boulevard, Mississauga, Ontario, Canada L5N 5S2.

2 Corresponding author. Email: Tianyou.Chen@CGG.com

Exploration Geophysics 46(1) 49-57 https://doi.org/10.1071/EG14027
Submitted: 13 March 2014  Accepted: 18 August 2014   Published: 25 September 2014

Abstract

An airborne time domain electromagnetic (TEM) system with high resolution and great depth of exploration is desired for geological mapping as well as for mineral exploration. The MULTIPULSE technology enables an airborne TEM system to transmit a high power pulse (a half-sine, for instance) and one or multiple low power pulse(s) (trapezoid or square) within a half-cycle. The high power pulse ensures good depth of exploration and the low power pulse allows a fast transmitter current turn off and earlier off-time measurement thus providing higher frequency signals, which allows higher near-surface resolution and better sensitivity to weak conductors. The power spectrum of the MULTIPULSE waveform comprising a half-sine and a trapezoid pulse clearly shows increased power in the higher frequency range (> ~2.3 kHz) compared to that of a single half-sine waveform. The addition of the low power trapezoid pulse extends the range of the sensitivity 10-fold towards the weak conductors, expanding the geological conductivity range of a system and increasing the scope of its applications. The MULTIPULSE technology can be applied to standard single-pulse airborne TEM systems on both helicopter and fixed-wing. We field tested the HELITEM MULTIPULSE system over a wire-loop in Iroquois Falls, demonstrating the different sensitivity of the high and low power pulses to the overburden and the wire-loop. We also tested both HELITEM and GEOTEM MULTIPULSE systems over a layered oil sand geologic setting in Fort McMurray, Alberta, Canada. The results show comparable shallow geologic resolution of the MULTIPULSE to that of the RESOLVE system while maintaining superior depth of exploration, confirming the increased geological conductivity range of a system employing MULTIPULSE compared to the standard single-pulse systems.

Key words: CDI, depth of exploration, geological conductivity range, high power, high resolution, MULTIPULSE, oil sands.


References

Carrigy, M. A., and Kramers, J. W., 1973, Guide to the Athabasca oil sands area: prepared for the Canadian Society of Petroleum Geologists Oil Sands Symposium, information series 65.

Duncan, A. C., Roberts, G. P., Buselli, G., Pik, J. P., Williamson, D. R., Rooke, P. A., Thorn, R. G., and Anderson, A., 1992, SALTMAP – Airborne EM for the environment: Exploration Geophysics, 23, 123–126
SALTMAP – Airborne EM for the environment:Crossref | GoogleScholarGoogle Scholar |

Hodges, G., and Chen, T., 2015, Geobandwidth: comparing time domain electromagnetic waveforms with a wire loop model: Exploration Geophysics, 46, 58–63
Geobandwidth: comparing time domain electromagnetic waveforms with a wire loop model:Crossref | GoogleScholarGoogle Scholar |

Lane, R., Green, A., Golding, C., Owers, M., Pik, P., Plunkett, C., Sattel, D., and Thorn, B., 2000, An example of 3D conductivity mapping using the TEMPEST airborne electromagnetic system: Exploration Geophysics, 31, 162–172
An example of 3D conductivity mapping using the TEMPEST airborne electromagnetic system:Crossref | GoogleScholarGoogle Scholar |

Liu, G., 1998, Effect of transmitter current waveform on airborne EM response: Exploration Geophysics, 29, 35–41
Effect of transmitter current waveform on airborne EM response:Crossref | GoogleScholarGoogle Scholar |

Macnae, J., 2007, Development in broadband airborne electromagnetics in the past decade, in B. Milkereit, ed., Proceedings of Exploration 07: Fifth Decennial International Conference on Mineral Exploration: 387–398.

Macnae, J., and Baron-Hay, S., 2010, Reprocessing strategy to obtain quantitative early time data from historic VTEM surveys: ASEG2010 21st Geophysical Conference, Extended Abstracts, 1–4.

Macnae, J., Mortimer, R., and Gilgallon, K., 2010, Deep conductor delineation through improved EMFlow data processing: ASEG2010 21st Geophysical Conference, Extended Abstracts, 1–4.

Reid, J., and Viezzoli, A., 2007, High resolution near surface airborne electromagnetics – SkyTEM survey for uranium exploration at Pells Range, WA: ASEG2007 19th Geophysical Conference, Extended Abstracts, 1–4.

Reid, J., Munday, T., and Fitzpatrick, A., 2007, High resolution airborne electromagnetic surveying for dryland salinity management: the Toolibin Lake SkyTEM case study, WA: ASEG2007 19th Geophysical Conference, Extended Abstracts, 1–5.

Sørensen, K. I., and Auken, E., 2004, SkyTEM – a new high-resolution helicopter transient electromagnetic system: Exploration Geophysics, 35, 194–202
SkyTEM – a new high-resolution helicopter transient electromagnetic system:Crossref | GoogleScholarGoogle Scholar |

Spies, B., and Frischknecht, F., 1991, Electromagnetic sounding, in M. Nabighian, ed., Electromagnetic methods in applied geophysics: SEG, Vol. 2, pp. 285–411.

Stolz, E. M., and Macnae, J, 1998, Evaluating EM waveforms by singular-value decomposition of exponential basis functions: Geophysics, 63, 64–74
Evaluating EM waveforms by singular-value decomposition of exponential basis functions:Crossref | GoogleScholarGoogle Scholar |